Pulmonex® II Xenon System

The Pulmonex® II Xenon System is the best choice for the performance of all regional lung ventilation studies. Safe, simple to operate and affordable.

Get a Quote

Description

Resistance-Free Breathing

The injected bolus of xenon will reach the patient exactly when desired. Oxygen may be added to the system any time during the study with the press of a button. An in-line cartridge containing Soda-Lime absorbs CO2, preventing acidosis. Large breathing passages, two 10-liter breathing bags (air-in and air-out) and motor-assisted airflow combine to provide resistance-free breathing.

Simple to Operate

All three steps of a Pulmonex® II study (start up, equilibrium imaging and washout) are controlled by a single valve handle on the front panel. The valve directs the motor-assisted flow of gases throughout the system. A manually adjusted 15-minute timer initiates all functions, then automatically shuts down the system to complete the study after patient and system washout. With controls conveniently located on the front panel, the user can operate the system and observe the patient and gamma camera from one position. Panel controls are clearly marked for each mode of the procedure with large viewing windows to make it easy to monitor the patient’s breathing. A trim, clean design, large handles and total mobility permit easy positioning of the system for studies in both seated and supine positions.

Three Simple Performance Positions

132-502 front

Illustration of Pulmonex II front panel controls

Position One:
Start – Patient breathes room air. System is charged with oxygen.

Position Two:
Single breath and equilibrium imaging – This is when you add Xe-133, either a bolus or a homogeneous mixture. An in-line cartridge containing Soda-Lime absorbs CO2 to prevent acidosis. The system is completely closed in this position with no chance of contaminating room air. When the patient equilibrates, the user switches the handle to washout position.

Position Three:
Washout – The patient is now breathing room air from a one-way valve through the delivery system and exhaling into the built-in charcoal trap. During washout a pump draws the patient’s expired breath through the activated charcoal trap. The xenon is stripped away and only clean air leaves the trap exit port.

Designed for Safety

Internal systems of the Pulmonex® II are shielded for patient and operator safety. The system features two built-in gas traps that operate with a blower fan. Exhaled xenon is pulled through activated charcoal housed within two .125″ lead shielded “U”-shaped traps. The double traps extend the life of your charcoal and provide a lengthy migration path for xenon effluent, allowing greater decay and absorption before exhaustion. A cartridge containing Drierite serves as a moisture absorber for air passing into the trap. The charcoal trap can then more effectively remove xenon effluent after each study. Airflow regulation of the trap blowers assure complete patient and system washout. Averaging 30-50 studies per month, the charcoal trap will last approximately one year; charcoal traps are easily replaced.

A disposable bacteriostatic filter, used in conjunction with a disposable mask or mouthpiece, prevents system contamination.

Features

  • Resistance-free breathing with 25-liter capacity
  • Complete .125″ lead shielding in upper cabinet for patient and operator safety
  • Easy access to replace Drierite and Soda-Lime cartridges
  • Effortless mobility for easy patient positioning
  • Stylish steel cabinet
  • Convenient built-in stainless steel tray for holding disposables, xenon gun, syringe, etc.

Specifications

  • Dimensions: 20.5″ w x 22″ depth x 48.5″ h (52.1 x 55.9 x 123.2 cm )
  • Motor: UL approved. 12 volt DC
  • Electrical Requirements: 115 VAC, 1 amp, 50/60 Hz
  • Casters: locking
  • Shipping Weight: 375 lb (172.5 kg)
  • Certifications: AAMI ES60601-1:2005+A1. CSA C22.2  #60601-1:2014 Ed. 3. IEC 60601-1-6:2010 Ed. 3+ A1.
  • Warranty: one year parts and labor

ETL Logo

Manuals

Manual, Pulmonex II Double-Trap Xenon System Operation
Manual, Pulmonex II Double-Trap Xenon System – Parts and Assembly Illustrations
Manual, Pulmonex II Double-Trap Xenon System – Troubleshooting
Manual, Dual Replacement Charcoal Cartridge Operation

Models and Ordering

132-503 Xenon System, Pulmonex® II Double-Trap, 115 VAC
Includes sampling of xenon products.

Sample Xenon Disposables Included with Pulmonex Xenon System:

The Pulmonex II Xenon System includes a sampling of disposables required to complete a xenon study. Disposables are packaged individually or in Xenon Convenience Kits. (The Xenon Kits include everything needed for a single study, including one with pre-measured CO2 soda-lime absorber and drierite cartridges.)

139-101 Drierite
130-019 Soda-Lime
132-680 Xenon Convenience Kit
with Face Mask and Bacteria Filter
132-691 Xenon Convenience Kit with Face Mask
(injection port) Bacteria Filter and Ultra Flex Tubing
132-692 Xenon Convenience Kit with Face Mask
(direct dose injection site), Bacteria Filter and Ultra-Flex Tubing
132-793 Xenon Convenience Kit
with Face Mask (direct dose injection site), Bacteria Filter, Ultra Flex Tubing, Drierite & Soda-Lime Cartridges
132-774 Xenon Convenience Kit
with Mouthpiece (injection adapter),
Bacteria Filter, Ultra-Flex Tubing and Nose Clip
130-900 Free Breathing Hose Kit

Related:

136-755 Xenon Trap Monitor
150-315 Dispenser, Xenon, Automatic
Includes 72″ Flexible Tubing with Luer-Lock Adapter
130-900 Pulmonex Kit, Free-Breathing Hose
132-504 Protective Cover, Pulmonex II

Replacement:

132-319 Charcoal Trap, Pulmonex II
132-555 Cartridge, Refillable, Soda-Lime or Drierite