Flow-RAM™

An innovative and low cost radio HPLC detector

Get a Quote

Description

The Flow-RAM is an innovative and low cost radio HPLC detector that addresses PET and SPECT production and research requirements. The instrument is compatible with all makes of HPLC systems and with the availability of the specifically designed range of detectors, the Flow-RAM is ideally suited for PET and Nuclear Medicine applications.

Item Numbers

 

0602-0084 Flow-RAM radio-HPLC system. Single channel with inputs for either PMT or PIN Diode detectors. Includes Laura full version software. Requires detector and PC
0602-0085 Flow-RAM radio-HPLC system. Single channel with inputs for either PMT or PIN Diode detectors. Includes Laura Academia software. Requires detector and PC
0602-0086 Flow-RAM radio-HPLC system. Single channel with inputs for either PMT or PIN Diode detectors. Includes Basic Control Software. Requires detector, chromatography software and PC
0602-0087 Flow-RAM radio-HPLC system. Dual channel inputs available simultaneously and independently for both PMT and/or PIN Diode detectors. Includes Laura full version software X 2. Requires detectors and PC
0602-0088 Flow-RAM radio-HPLC system. Dual channel inputs available simultaneously and independently for both PMT and/or PIN Diode detectors. Includes Laura Academia software X 2. Requires detectors and PC
0602-0089 Flow-RAM radio-HPLC system. Dual channel inputs available simultaneously and independently for both PMT and/or PIN Diode detectors. Includes Basic Control software. Requires detectors, chromatography software and PC
0602-0090 Hand held wireless preloaded with Laura Mobile (Flow-RAM)
0602-0091 1 Year Instrument Technical Assistance
0602-0092 1 Year Instrument Service Contract

Get a Quote

Features

  • GLP/GMP compliance as standard
  • A wide range of detectors for all Nuclear Medicine and PET Radionuclides
  • Bespoke lead shielding to limit the background interference
  • Intelligent and informative front end display
  • Flexibility; two detectors can be connected to the same instrument simultaneously AND independently of one another to provide a two in one instrument
  • USB connection for power supply, instrument control and data collection, rather than the now outdated and slow serial output of older systems
  • Flow-RAM is the first radiodetector of its type to offer stand alone control of data collection through a pocket digital assistant via a Bluetooth™ wireless link.

Get a Quote

Detectors

0602-0093 PMT – 1” NaI detector suitable for detection of high-energy gamma radionuclides for HPLC and TLC (not suitable for radio-TLC of PET isotopes). Includes HV/signal C cable. (requires shield and flow cell)
0602-0094 PMT – 2” NaI detector for high energy gammas. Includes HV/signal C cable. (requires shield and flow cell)
0602-0095 PMT – Plastic Scintillator detector suitable for detection of PET isotopes for TLC and high energy beta radionuclides for HPLC. Includes HV/signal C cable
0602-0096 PMT – NaI detector for 125I, and other low energy gammas. Includes HV/signal C cable. (requires shield and flow cell)
0602-0097 Well Type PMT – NaI detector with 4Pi counting geometry. Well: 1.7 cm Dia x 3.9 cm L Detector: 4.5 x 5.1 cm. Requires lead shield PJ-FXX-15
0602-0098 Miniature PIN Diode radio-HPLC detector for high activity monitoring of gammas up to 1 Curie
0602-0099 Miniature CsI/PIN Diode radio-HPLC detector for high energy gammas

Get a Quote

Shields

0602-0100 Five part 1’’ lead shield for PMT detectors. Ideal for low-energy isotopes. Includes flow cell
0602-0101 Five part 2’’ lead shield for PMT detectors. Ideal for QC of PET/SPECT products in areas with high background. Includes flow cell
0602-0102 Five part 3’’ lead shield for PMT detectors. Ideal for QC of PET/SPECT products in areas with high background. Includes flow cell
0602-0103 Lead shielded holder and flow cell for PIN Diode detectors
0602-0104 Six part 2’’ lead shield for 2” NaI/PMT detectors/PN-FXX-04. Ideal for QC of PET/SPECT products in areas with high background. Includes flow cell
0602-0105 Six part 2” lead shield for the 2’’ NaI/PMT well type detector PN-FXX-14
0602-0106 Sleeve insert for lead shield (PJ-FXX-11) that is suitable for PIN Diode detectors

Get a Quote

Validation

0602-0107 Single output Flow-RAM hardware IQ/OQ
0602-0108 Dual output Flow-RAM hardware IQ/OQ